Mocom Milldrop Specifications Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 102
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
4. INSTALLATION
10
INSTALLATION
INTRODUCTION
The first and fundamental step in achieving good sterilizer operation, long life and complete
use of its features is a correct, careful installation. Moreover, this precaution will avoid the
danger of physical injury or property damage, not to mention malfunctions and damage to the
machine. So, please follow the instructions in this chapter scrupulously.
NOTE
M.O.COM.
CUSTOMER SUPPORT (SEE
A
PPENDIX Z) WILL ANSWER YOUR QUESTIONS
AND PROVIDE ADDITIONAL INFORMATION
.
T
HE STERILIZER HAS PASSED ALL REQUIRED INSPECTIONS BEFORE BEING PLACED ON
THE MARKET
. IT DOES NOT REQUIRE ANY ADDITIONAL CALIBRATION BEFORE BEING
PLACED IN SERVICE
.
Dimensions and weight
B and B+ B
2
A. Height (total) 420 mm 420 mm
B. Width (total) 480 mm 480 mm
C. Depth (excluding rear
connections)
560 mm 660 mm
Total weight 58 kg 63 kg
Electricity
The electrical system to which the sterilizer will be connected must be suitably dimensioned
based on the electrical characteristics of the device. This information is shown on the back of
the machine.
COMPARTMENT
DIMENSIONS FOR
BUILT-IN
INSTALLATIONS
When installing the sterilizer inside a cabinet, you must
provide adequate space all around the device to
provide effective ventilation as well as a large enough
opening in the back that, in addition to allowing the
passage of the power cord will also provide an
adequate air flow and the consequent optimum cooling
of the heat exchanger.
The compartment where the steriliser will be kept must
have the following minimum dimensions:
Dimensions and weight
B and B+ B
2
A. Height 500 mm 500 mm
B. Width 580 mm 580 mm
C. Depth 600 mm 700 mm
WARNING
COMPARTMENT DIMENSIONS LESS THAN THOSE SHOWN MAY
COMPROMISE THE CORRECT CIRCULATION OF AIR AROUND THE
DEVICE AND MAY NOT PROVIDE ADEQUATE COOLING, WITH THE
CONSEQUENT DETERIORATION OF PERFORMANCE AND/OR POSSIBLE
DAMAGE.
NOTE
I
F THE MAIN SWITCH IS INACCESSIBLE WHEN INSTALLED IN THE COMPARTMENT, USE AN
ELECTRIC PLUG THAT INCORPORATES AN ON
/OFF SWITCH.
D
O NOT REMOVE THE UPPER COVER OR ANY OTHER EXTERNAL PART. WHEN INSTALLED
IN THE COMPARTMENT
, THE DEVICE MUST BE COMPLETE WITH ALL ITS PARTS.
P
LEASE REFER TO APPENDIX A (TECHNICAL CHARACTERISTICS) FOR COMPLETE
TECHNICAL DATA
.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 101 102

Comments to this Manuals